Deprecated: Creation of dynamic property cls_session::$session_data_table is deprecated in /www/sites/www.188bio.com/index/systems/cls_session.php on line 49
VivanTechnologies/ViPrimePLUS Lyophilized One Step qRT-PCR Master Mix/Applied Biosystems 7500 platform188bio精品生物—专注于实验室精品爆款的电商平台 - 蚂蚁淘旗下精选188款生物医学科研用品
您好,欢迎您进入188进口试剂采购网网站! 服务热线:4000-520-616
蚂蚁淘商城 | 现货促销 | 科研狗 | 生物在线
产品资料

VivanTechnologies/ViPrimePLUS Lyophilized One Step qRT-PCR Master Mix/Applied Biosystems 7500 platform

DescriptionViPrimePLUS Lyophilized One Step qRT-PCR Master Mix is next generation first choice mix for a convenient and rapid one step real-time PCR reaction set up. The master mix has been freeze-dried to produce a room temperature stable preparation. The freeze-dried master mix contains unique thermostable M-MULV enzyme, Taq DNA polymerases, MgCl2 and buffer components at optimal concentration. ViPrimePLUS Lyophilized One Step qRT-PCR Master Mix has same optimal performance as ViPrimePLUS One Step qRT-PCR Master Mix and ViPrimePLUS One Step qRT-PCR Green Master Mix. The lyophilized qRT-PCR Master Mix can detect extremely low copy number targets of RNA templates in one step complete system. The removal of separate reverse transcription step not only reduces errors and time to obtain results, but also leads the qRT-PCR reaction to optimum sensitivity and specificity. ViPrimePLUS Lyophilized One Step qRT-PCR Master Mix is used with supplied re-suspension buffer and ROX dye; hence hardware platforms that need ROX as passive reference dye can be used in standard cycling conditions.

Features

  • Convenient and rapid real time PCR reaction set up
  • Lyophilized form – room temperature stable preparation
  • Equipped with thermostable M-MULV enzyme and Taq DNA Polymerase
  • Reliable quantification of low-abundance transcripts very specifically with high efficiency
  • Compatible with most of the real-time PCR platforms

Kit Component

  • 3 x Lyophilized qPCR MasterMix
  • 1 x Lyophilized ROX
  • 4 x Re-suspension buffer

Master Mixes Selection Guidelines for System CompatibilityTo calibrate a real-time PCR reaction, the various formulations of Master Mixes are available for most of the platforms.

Real-time PCR platformsROX re-suspension volumeROX addition per tube of master mix
Applied Biosystems 7000, 7700, 7900, 7300 StepOne, StepOnePLUS and ViA7 platforms, Roche capillary Lightcyclers.100µl20µl
All Stratagene platforms200µl15µl
Applied Biosystems 7500 platform700µl10µl
All other machinesNot RequiredNot Required

Ordering Information

Catalog NoDescriptionPack Size
QLMM06ViPrimePLUS Lyophilized One Step qRT-PCR Master Mix150 reactions

DownloadManual

ViPrimePLUS Lyophilized One Step qRT-PCR Master Mix

新闻动态
行业前沿
技术文章
最新产品